Call Us

Call Us

08071930454
Cleaveland Flash & Fire Point Apparatus

Cleaveland Flash & Fire Point Apparatus

10500 INR/Piece

Product Details:

  • Usage For Lab Use
  • Automation Grade Manual
  • Product Type Flash & Fire Point Apparatus
  • Voltage 230V AC
  • Temperature Range Ambient to 400C
  • Power Source Electric
  • Material Mild Steel
  • Click to View more
X

Cleaveland Flash & Fire Point Apparatus Price And Quantity

  • 1 Piece
  • 10500 INR/Piece

Cleaveland Flash & Fire Point Apparatus Product Specifications

  • 1C
  • White
  • Mild Steel
  • Flash & Fire Point Apparatus
  • Ambient to 400C
  • Approx. 10 kg
  • Electric
  • CLE-01
  • 230V AC
  • Up to 500 ml
  • 300 x 220 x 350 mm
  • Corrosion Resistant, Easy Ignition Method
  • Mild Steel Housing, Brass & Stainless Steel Test Cup
  • 50 Hz
  • Analog Dial
  • For Lab Use
  • Manual
  • Up to 400C
  • Flash & Fire Point Apparatus
  • Test Cup, Heating Plate, Thermometer Holder

Cleaveland Flash & Fire Point Apparatus Trade Information

  • Cash in Advance (CID), Cash Advance (CA)
  • 1 Piece Per Day
  • 2-3 Days
  • Western Europe, South America, Middle East, Central America, Eastern Europe, Asia, North America, Australia, Africa
  • All India

Product Description

Leveraging on our immense market experience, we have emerged as an eminent manufacturer, exporter and supplier of Cleaveland Flash & Fire Point Apparatus. Equipped with a 1,000 watt nickel-chromium heater, this apparatus is widely used in chemical laboratories, food processing and other allied industries. This apparatus is made with the utilization of quality approved components under the strict direction of experienced professionals. Offered Cleaveland Flash & Fire Point Apparatus is immensely preferable and demanded due to its smooth functioning and ruggedness.

Features:

  • Simple functionality

  • Longer service life

  • Excellent performance

  • High operational fluency

Specifications:

Equipped with a 1,000 watt nickel-chromium heater with step-less variable heat control for accurate repeat setting of temperature rate rise per specifications. Heater unit is enclosed in a stainless steel housing with cooling vents. Test flame applicator and thermometer support are constructed of machined nickel-plated brass. Dimensions (L x W x H, inches): 10 x 51/2 x 14; weight: 12 lbs.

Determines Cleaveland Flash & Fire Point Apparatus method. Consists of test flame applicator, brass test cup, thermometer support, heating plate and electric heater. Applicator is precisely aligned per specifications and pivots for the test flame application at specified temperature intervals. Hinged thermometer support raises to facilitate placement and removal of test cup. Adjust flame size using built-in needle valve and comparison bead.



Reliable Flash and Fire Point Determination

With this apparatus, laboratories can measure the flash and fire points of various substances under controlled conditions, ensuring adherence to industry and safety standards. The device provides consistent heating through an electrically powered heating plate, making it suitable for testing petroleum, paints, and lubricants.


Durable Build and Corrosion Resistance

Constructed with a combination of mild steel housing and brass or stainless steel test cups, the unit offers high durability and resistance to corrosion. The heat-resistant bakelite handle ensures safe handling during tests, enhancing the apparatus's longevity and performance in professional settings.


Precision and Ease of Use

Manual operation grants precise control over the testing process. The analog dial display and adjustable heating rate regulator allow users to monitor temperatures accurately, supported by a thermometer range of -10C to 360C. Effortless ignition and clear display simplify usage for technicians and researchers.

FAQ's of Cleaveland Flash & Fire Point Apparatus:


Q: How does the Cleveland Flash & Fire Point Apparatus work for flash and fire point determination?

A: The apparatus operates using the Cleveland Open Cup Method, where the sample is heated in an open brass or stainless steel test cup. The temperature is gradually increased with the variable regulator until the substance's vapors ignite with a gas test flame, indicating the flash or fire point.

Q: What materials are used in the construction of the test cup and housing?

A: The test cup is available in both brass and stainless steel options for enhanced corrosion resistance. The main housing of the apparatus is manufactured from mild steel, providing durability and stability during laboratory testing.

Q: When should this apparatus be used in quality control testing?

A: It is best used during quality analysis and approval processes for petroleum products, lubricants, and paints, where flash and fire point values are critical for verifying safety and formulation standards.

Q: Where is this apparatus suitable for use?

A: The Cleveland Flash & Fire Point Apparatus is designed for laboratory environments across industries such as petrochemicals, paints, and lubricants, and is intended for use by researchers, technicians, and analysts in test labs.

Q: What is the process of testing with this apparatus?

A: Set up the sample in the test cup, regulate heating with the manual control, and monitor the temperature using the analog dial. When vapor ignition occurs with the test flame, record the flash and fire point as specified in the Cleveland Open Cup Method.

Q: What are the benefits of using this apparatus for flash point testing?

A: Benefits include precise temperature control, robust and corrosion-resistant construction, safe handling due to the bakelite handle, and compliance with recognized testing standards, ensuring reliable results for product safety and regulatory checks.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Oil and Petroleum Testing Instruments' category



Back to top