ELECTRICAL CONDUCTIVITY METER (Microprocessor based)

ELECTRICAL CONDUCTIVITY METER (Microprocessor based)

10500 INR/Piece

Product Details:

  • Usage For laboratory Use
  • Temperature Range 0C to 100C
  • Capacity 20000 S/cm
  • Voltage 230 V
  • Model No ECM-104
  • Measurement Range 0 to 200 mS/cm
  • Accuracy 1% FS 1 Digit
  • Click to View more
X

ELECTRICAL CONDUCTIVITY METER (Microprocessor based) Price And Quantity

  • 1 Piece
  • 10500 INR/Piece

ELECTRICAL CONDUCTIVITY METER (Microprocessor based) Product Specifications

  • Microprocessor Based Conductivity Meter
  • Automatic Temperature Compensation
  • 0C to 100C
  • 50 Hz
  • 20000 S/cm
  • 0 to 200 mS/cm
  • 230 V
  • ECM-104
  • Automatic
  • 1% FS 1 Digit
  • Mild Steel
  • Approx 2 kg
  • CONDUCTIVITY METER
  • Digital
  • 230V AC
  • Microprocessor, Conductivity Cell, LCD Display
  • White
  • For laboratory Use
  • Mild Steel
  • 275 mm x 175 mm x 76 mm

ELECTRICAL CONDUCTIVITY METER (Microprocessor based) Trade Information

  • Cash in Advance (CID), Cash Advance (CA)
  • 1 Piece Per Day
  • 2-3 Days
  • Western Europe, Australia, Eastern Europe, Central America, Middle East, South America, Asia, North America, Africa
  • All India

Product Description

Leveraging on our vast industry experience, we are offering our clients a finest quality range of Electrical Conductivity Meter. The provided meter is manufactured using optimum quality raw material and the latest technology by our skilled team of professionals. Offered meter measures the electrical conductivity in a solution. It is commonly used in hydroponics, aquaculture and freshwater systems to monitor the amount of nutrients, salts or impurities in the water. Moreover, this Electrical Conductivity Meter is made available in different specification at affordable prices to the clients.

Features:

  • Auto Calibration

  • Storage of 100 samples

  • Printer attachment facility

  • Soft touch membrane keys

Specifications

 

Display

16 x 2 alpha numeric LCD display

 

Range

0.1 us to 100mS (6 decadic ranges)

 

Resolution

0.1

 

Accuracy

+ 1% of F.S. + 1 digit

 

Calibration

Auto / Manual

 

Temperature Range

0 to 100oC

 

Cell Content

0.1 to 5.0

 

Storage

Up to 100 samples

 

Power

230V + 50Hz

 

Accessories

Conductivity Cell, Temperature probe, Stand, Clamp, Dust cover, Manual

 

Product Range

Photo Colorimeters, Spectrophotometers, Digital pH Meters, Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis Kits



Advanced Measurement Technology

Equipped with a microprocessor core and a high-precision conductivity cell, this meter provides rapid and accurate readings. Digital calibration eliminates manual errors, ensuring reliable data in laboratory testing. Its large alphanumeric LCD simplifies real-time monitoring for researchers and technicians.


User-Friendly Features

The device includes automatic temperature compensation across 0C to 100C and supports digital calibration, making it easy to operate and maintain. Accessories such as the electrode, dust cover, and operation manual assist in quick setup and routine use, enhancing user experience.


Flexible Communication and Construction

With an RS232 communication port, data can be efficiently transferred or logged for further analysis. The meter is housed in a sturdy mild steel casing, combining durability with a sleek white finish. Compact dimensions make it suitable for various laboratory settings.

FAQ's of ELECTRICAL CONDUCTIVITY METER (Microprocessor based):


Q: How is digital calibration performed on the ECM-104 Conductivity Meter?

A: Digital calibration is carried out through the meter's user interface, allowing accurate adjustment without manual potentiometers. The process involves using a calibration solution and following step-by-step prompts on the LCD display, ensuring precise setup for measurements.

Q: What benefits does automatic temperature compensation provide in conductivity measurements?

A: Automatic temperature compensation (ATC) ensures that conductivity readings remain precise despite fluctuations in sample temperature. This feature adjusts the readings within the 0C to 100C range, eliminating errors caused by thermal variations during laboratory analysis.

Q: When should the supplied electrode be replaced or maintained?

A: Electrode maintenance or replacement depends on usage frequency and sample types. Regular cleaning and calibration are recommended; replacement may be necessary if performance declines or readings become unstable. Refer to the operation manual for specific care instructions.

Q: Where can data from the ECM-104 meter be exported or logged?

A: Data can be transmitted via the built-in RS232 communication port to a computer or data logger. This feature enables efficient digital record-keeping and integration into laboratory data management systems.

Q: What is the typical process for measuring conductivity using this instrument?

A: Begin by calibrating the instrument with a standard solution, insert the electrode into the test sample, and ensure temperature compensation is set. The large LCD will display real-time conductivity values for immediate analysis.

Q: How does the microprocessor contribute to measurement accuracy?

A: The integrated microprocessor processes incoming signals from the conductivity cell, automatically applying temperature corrections and calibration factors. This ensures high-accuracy readings with minimal user intervention.