Product Description
We take massive pride to introduce ourselves as one of the reliable manufacturers and suppliers of Applanation Tonometer. It is used to measure the intraocular pressure while working under the slit lamp. Adjustable measuring pressure ensures the working stability and accurate measurement of tonometer for long time. We manufacture the Applanation Tonometer using high quality materials, sourced from authentic vendors. We offer our equipments at affordable prices.
Features:
-
Easy maintenance
-
Durable quality
-
Accurate measurement
Further Details:
It shows in mm HG, with a precision of +-0.3. Our range is designed using quality basic materials on the basis of Goldman tonometer. The wide array of equipment find huge demand in the industry for its durability, performance and easy maintenance characteristic. Furthermore, we make sure that our range is free from any defects and ideal for application.
Technical Specifications:
-
When used with Slit Lamp, it can be used to examine the eyes and measure the ocular pressure.
-
Accurate measurement and total tolerance is less than 0.066 Kpa (0.55Hg).
-
Directly get the ocular pressure.
-
The measured ocular pressure is not affected by hardness of eye. The affected ocular volume is just 0.56 cubic millimeter.
-
Adjustable measuring ensures the long-term stability and reliability.
Accurate Intraocular Pressure AssessmentEngineered for precise measurement, the Applanation Tonometer uses a precision-ground optical lens coupled with an applanation prism. The analog dial provides clear readings across a 0-80 mmHg range, minimizing corneal distortion and supporting dependable diagnostics for glaucoma and related conditions.
Versatile Slit Lamp CompatibilityThis tonometer is designed to fit most standard slit lamps, simplifying integration into existing ophthalmic workstations. Mounting is quick and stable, allowing swift transitions between patient assessments and ensuring uninterrupted clinical workflows.
Durable, Hygienic, and User-FriendlyManufactured with medical-grade stainless steel and finished in corrosion-resistant matte/satin, the instrument is robust and easy to disinfect. The prism is sterilizable via autoclaving or chemical disinfection, meeting rigorous hygiene standards for safe patient care in varied environments.
FAQ's of Applanation Tonometer:
Q: How do you calibrate the Applanation Tonometer before use?
A: To calibrate, perform manual external calibration using the adjustment mechanism provided. Ensure the analog dial reads accurately, following the manufacturer's instructions before clinical use for optimal measurement results.
Q: What is the recommended environment for operating this tonometer?
A: Operate the Applanation Tonometer within a temperature range of 0C to 40C and humidity below 85%. These conditions ensure consistent performance and preserve equipment longevity.
Q: When should the prism be sterilized and by what method?
A: Sterilize the applanation prism before and after each patient examination. Use either autoclaving or approved chemical disinfection methods, as the prism is designed to withstand both processes safely.
Q: Where does the Applanation Tonometer mount on ophthalmic equipment?
A: This device mounts directly onto the slit lamp using the designated slit lamp mount, ensuring secure positioning and easy access during intraocular pressure measurement.
Q: What benefits does optical measurement offer in this tonometer?
A: Optical measurement ensures highly accurate intraocular pressure readings while minimizing corneal distortion. This technology upholds diagnostic reliability essential for glaucoma screening and management.
Q: How is intraocular pressure displayed, and what range is covered?
A: The measurement is displayed on an analog dial, covering a range from 0 to 80 mmHg. The display is clear and easy to read, facilitating swift assessment and documentation.