Call Us

Call Us

08071930454
Pensky Martin Flash Point Apparatus

Pensky Martin Flash Point Apparatus

10500 INR/Piece

Product Details:

  • Model No Pensky-Martin Standard
  • Material Stainless Steel
  • Power Source Electric & Gas
  • Feature Manual & Precise Detection
  • Color Silver
  • Accuracy 1 C
  • Frequency 50 Hz
  • Click to View more
X

Pensky Martin Flash Point Apparatus Price And Quantity

  • 1 Piece
  • 10500 INR/Piece

Pensky Martin Flash Point Apparatus Product Specifications

  • Electric & Gas
  • Manual & Precise Detection
  • Manual
  • Flash Point Apparatus
  • Analog
  • Stainless Steel
  • Ambient to 370C
  • Closed Cup Apparatus
  • Up to 370C
  • Test Cup, Lid Assembly, Heating Unit, Thermometer
  • Silver
  • Standard 70 ml (as per IS:1448) / Optional sizes available
  • 230V AC
  • Pensky-Martin Standard
  • 50 Hz
  • 1 C
  • For Lab Use
  • Approx. 7 kg
  • Stainless Steel with Brass Cup
  • Approx. 240 x 220 x 300 mm

Pensky Martin Flash Point Apparatus Trade Information

  • Cash in Advance (CID), Cash Advance (CA)
  • 1 Piece Per Day
  • 2-3 Days
  • Western Europe, Middle East, Central America, Eastern Europe, South America, Asia, North America, Australia, Africa
  • All India

Product Description

We are an unparalleled name in presenting premium quality Pensky Martin Flash Point Apparatus to our clients. Fitted with insulated handle and locking arrangement near cup plange, this apparatus is widely used for determination of closed cup Flash Point of Fuel Oil, Cut Back asphalts, other viscous material. Fabricated with the help of cutting-edge technology under the stern guidance of our seasoned professionals, this apparatus is available in multiple technical specific options as per the need of our clients. Furthermore, this Pensky Martin Flash Point Apparatus goes through on certain parameters to ensure its performance and longer working life.

Features:

  • Brass Test cup with handle

  • Removable cup cover

  • Spring operated rotating shutter having Piolet Jet

  • Stirrer with flexible shaft



Accurate Flash Point Detection for Multiple Applications

Designed for laboratories, the Pensky Martin Flash Point Apparatus delivers reliable and repeatable results in petroleum, chemical, paint, varnish, and oil testing. Its adjustable heating rate and dual ignition options (electric or gas flame) ensure flexibility and safety for a wide range of volatile samples. The brass test cup measures up to 370C, making the apparatus suitable for compliance checks and routine quality control.


Robust Construction with Premium Materials

Built with a stainless steel body and a brass cup, the apparatus withstands rigorous usage and resists chemical corrosion. The equipment's mechanical stirrer and analog display promote operator control and straightforward measurement readings, while compact dimensions and moderate weight enhance laboratory adaptability. Compliance with IS:1448, ASTM D93, and IP34 ensures universal acceptance and reliability.

FAQ's of Pensky Martin Flash Point Apparatus:


Q: How is the flash point determined using the Pensky Martin Flash Point Apparatus?

A: The flash point is determined by gradually heating a sample in the closed brass cup while stirring. An ignition source (electric or gas flame) is applied at specific intervals. The temperature at which a flash appears on the sample surface is recorded as the flash point.

Q: What types of samples can be tested with this apparatus?

A: This instrument is suitable for testing petroleum products, paints, varnishes, chemicals, and oils, making it versatile for laboratories in the energy, chemical, and manufacturing sectors.

Q: When should the flash point test be performed in a laboratory setting?

A: Flash point tests are conducted during quality control, compliance verification, safety checks, and research and development processes to determine the flammability and safe handling temperatures of different substances.

Q: Where is the Pensky Martin Flash Point Apparatus typically used?

A: The device is most commonly used in analytical laboratories, quality control departments, and R&D centers across various industries such as petroleum refineries, paint manufacturers, and chemical plants.

Q: What is the procedure for operating the Pensky Martin Apparatus?

A: Fill the test cup with the sample, assemble the apparatus, adjust the stirrer speed, and set the heating rate. Apply the ignition source at prescribed temperature intervals and observe for a flash. Record the temperature from the analog display for the flash point reading.

Q: What are the key benefits of using this apparatus?

A: Benefits include high measurement accuracy (1C), compliance with global standards, durable construction, precise temperature control up to 370C, and the ability to test multiple sample types with manual or gas ignition.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Oil and Petroleum Testing Instruments' category



Back to top